The placement of a tracheal airway stent is typically performed through a minimally invasive procedure using endoscopy. Here’s a general overview of the process:


1. **Pre-procedure Preparation**:

- The patient is assessed and may undergo imaging studies to evaluate the extent of the airway obstruction.

- Anesthesia options include local anesthesia with sedation or general anesthesia, depending on the patient’s condition and the complexity of the procedure.


2. **Endoscopic Visualization**:

- The procedure begins with the insertion of a flexible endoscope (a thin tube with a camera) into the trachea through the mouth or nose. This allows the physician to visualize the airway and the specific area needing support.


3. **Measurement and Selection**:

- The physician assesses the size and shape of the trachea to select the appropriate stent. This may involve measuring the diameter and length of the affected area.


4. **Stent Insertion**:

- The stent, often mounted on a delivery system, is carefully positioned at the site of narrowing. If it is an expandable stent, it may be deployed using a balloon or by self-expansion.


5. **Confirmation**:

- Once in place, the position of the stent is confirmed through imaging techniques, such as fluoroscopy or direct visualization with the endoscope.


6. **Post-procedure Care**:

- The patient is monitored in a recovery area to assess breathing and any immediate complications.

- Follow-up appointments are scheduled to monitor the stent's position and function and to manage any potential issues.


The entire process aims to restore airflow and improve the patient’s respiratory function while minimizing discomfort and recovery time.


Contact us quickly to get the latest product quotation !
Leave a Message
Contact us

PRODUCTS

LINKS

CONTACT

Company Address: Room 302 , 3rd Floor, Building 6, No. 688, Bin an Road Hangzhou, China
Postal Code: 310052
Whatsapp/Wechat: +86-17767267187
Email:ljh@tangjimedical.com
Office:+86-571 87839895
Copyright © 2017-2022 Hangzhou Tangji Medical Technology Co., Ltd.. All rights reserved.