Product Price $95-$295/ Piece
Type: Medical stent
Stent position: Intestinal stent
Material: Nitinol super elastic wire
Covering materials: silicone, PE, ePTFE, etc.
Stent diameter: 18mm-20mm
Bracket length: 60mm-80mm
Customization: support customization
Sample: Support sample
Certificate: CE ISO etc.
Intestinal stent
Availability: | |
---|---|
Overview
Intestinal stent
Characteristic
1.Continued gentle radial tensile force, effectively expands the stenosis, reducing the patients’ discomfort.
2.Imaging markers of the stents are clear visible under image equipment. Positioning is more accurate.
1.Pylorus stent
Usage
Used for malignant lesions caused by gastric outlet stenosis or obstruction, suitable for ministry of pyloric stenosis.
Characteristic
Conform to the pylorus of physiological anatomy port design.
Specification table (for pylorus stents):
Stent diameter (mm) | Port diameter (middle/near-end) | Length(mm) | Specification of Introducer system (Pipe diameter Fr x effective working length mm) | Head end shape |
18 | 18/45 | 60/80 | 18Fr x1350 | Single ball-single horn |
20 | 20/45 | 60/80 | 18Fr x1350 |
Stent System Structure Sketch
2.Duodenal stent(OTW/TTS)
Usage
Used for duodenal stenosis or obstruction caused by malignant lesions.
Characteristics
Excellent flexibility, physiological bending conforms to the duodenum.
Specification table (for duodenal stents):
Stent diameter (mm) | Middle/end (mm) | Length(mm) | Specification of Introducer system (Pipe diameter Fr x effective working length mm) |
18 | 18/25 | 60/80/100/120 | 18Fr x 1350(OTW) |
20 | 20/25 | 60/80/100/120 | 18Fr x 1350(OTW) |
18 | 18/25 | 60/80/100 | 10Fr x 1850(TTS) |
20 | 20/25 | 60/80/100 | 10Fr x 1850(TTS) |
Stent System Structure Sketch
3.Colon stent
Usage
Used to treat colon narrow or obstruction caused by malignant lesions.
Characteristics
Spherical structure design, reduces the stimulation, not easy to shift.
Specification table (for colon stents):
Stent diameter (mm) | Port diameter (middle/near-end) | Length(mm) | Specification of Introducer system (Pipe diameter Fr x effective working length mm) |
20 | 20/26 | 60/80/100 | 10Fr x2400(TTS) |
25 | 25/30 | 60/80/100 | 10Fr x2400(TTS) |
28 | 28/36 | 60/80/100 | 10Fr x 1000(OTW) |
30 | 30/36 | 60/80/100 | 10Fr x 1000(OTW) |
4.Rectum stent (OTW/TTS)
Usage
Used to treat colon narrow or obstruction caused by malignant lesions.
Characteristics
Spherical structure design, reduces the stimulation, not easy to shift.
Specification table (for rectum stents):
Stent diameter (mm) | Port diameter (middle/near-end) | Length(mm) | Specification of Introducer system (Pipe diameter Fr x effective working length mm) |
20 | 20/26 | 60/80/100 | 10Fr x2400(TTS) |
25 | 25/30 | 60/80/100 | 10Fr x2400(TTS) |
28 | 28/36 | 60/80/100 | 10Fr x 1000(OTW) |
30 | 30/36 | 60/80/100 | 10Fr x 1000(OTW) |
Stent System Structure Sketch
The code of stent shape(for intestinal stents)
A.Straight ends F. Double ball ends G. Single cup end
C. Single tulip end K. Tulip end-ball end H. Double cup ends
D. Double tulip ends P. Tulip end-cup end W. Segmented with double cup ends
E. Single ball end Q. Cup end-ball end
FAQ
A6: For bulk order, the box can be customized, we will confirm design before packaging. But for the sample order, we can only use our regular box.
Contact
Overview
Intestinal stent
Characteristic
1.Continued gentle radial tensile force, effectively expands the stenosis, reducing the patients’ discomfort.
2.Imaging markers of the stents are clear visible under image equipment. Positioning is more accurate.
1.Pylorus stent
Usage
Used for malignant lesions caused by gastric outlet stenosis or obstruction, suitable for ministry of pyloric stenosis.
Characteristic
Conform to the pylorus of physiological anatomy port design.
Specification table (for pylorus stents):
Stent diameter (mm) | Port diameter (middle/near-end) | Length(mm) | Specification of Introducer system (Pipe diameter Fr x effective working length mm) | Head end shape |
18 | 18/45 | 60/80 | 18Fr x1350 | Single ball-single horn |
20 | 20/45 | 60/80 | 18Fr x1350 |
Stent System Structure Sketch
2.Duodenal stent(OTW/TTS)
Usage
Used for duodenal stenosis or obstruction caused by malignant lesions.
Characteristics
Excellent flexibility, physiological bending conforms to the duodenum.
Specification table (for duodenal stents):
Stent diameter (mm) | Middle/end (mm) | Length(mm) | Specification of Introducer system (Pipe diameter Fr x effective working length mm) |
18 | 18/25 | 60/80/100/120 | 18Fr x 1350(OTW) |
20 | 20/25 | 60/80/100/120 | 18Fr x 1350(OTW) |
18 | 18/25 | 60/80/100 | 10Fr x 1850(TTS) |
20 | 20/25 | 60/80/100 | 10Fr x 1850(TTS) |
Stent System Structure Sketch
3.Colon stent
Usage
Used to treat colon narrow or obstruction caused by malignant lesions.
Characteristics
Spherical structure design, reduces the stimulation, not easy to shift.
Specification table (for colon stents):
Stent diameter (mm) | Port diameter (middle/near-end) | Length(mm) | Specification of Introducer system (Pipe diameter Fr x effective working length mm) |
20 | 20/26 | 60/80/100 | 10Fr x2400(TTS) |
25 | 25/30 | 60/80/100 | 10Fr x2400(TTS) |
28 | 28/36 | 60/80/100 | 10Fr x 1000(OTW) |
30 | 30/36 | 60/80/100 | 10Fr x 1000(OTW) |
4.Rectum stent (OTW/TTS)
Usage
Used to treat colon narrow or obstruction caused by malignant lesions.
Characteristics
Spherical structure design, reduces the stimulation, not easy to shift.
Specification table (for rectum stents):
Stent diameter (mm) | Port diameter (middle/near-end) | Length(mm) | Specification of Introducer system (Pipe diameter Fr x effective working length mm) |
20 | 20/26 | 60/80/100 | 10Fr x2400(TTS) |
25 | 25/30 | 60/80/100 | 10Fr x2400(TTS) |
28 | 28/36 | 60/80/100 | 10Fr x 1000(OTW) |
30 | 30/36 | 60/80/100 | 10Fr x 1000(OTW) |
Stent System Structure Sketch
The code of stent shape(for intestinal stents)
A.Straight ends F. Double ball ends G. Single cup end
C. Single tulip end K. Tulip end-ball end H. Double cup ends
D. Double tulip ends P. Tulip end-cup end W. Segmented with double cup ends
E. Single ball end Q. Cup end-ball end